Back to top
08045476597
Send SMS Send Inquiry
MPI Consumables
MPI Consumables

MPI Consumables

MPI Consumables Specification

  • Number of Specimens
  • Single or multiple (varies by test)
  • Mounting Type
  • Handheld or accessory-based
  • Automation Grade
  • Manual
  • Accuracy
  • Product dependent, typical for MPI
  • Measuring Range
  • As per relevant standard requirements
  • Application
  • Magnetic Particle Inspection (MPI) analysis
  • Specimen Size
  • Standard per ASTM/IS standards
  • Operating Voltage
  • NA for consumables
  • Temperature
  • 10C to 50C
  • Features
  • High sensitivity, consistent performance, easy application
  • Equipment Type
  • MPI Consumables (Inks, Sprays, Powders, Accessories)
  • Power Supply
  • Not required (for consumables)
  • Response Time
  • Immediate (upon application)
  • Test Range
  • Dependant on specific consumable (refer individual type)
  • Resolution
  • Product dependent
  • Humidity
  • Up to 80% RH non-condensing
  • Usage
  • For NDT Magnetic Particle Testing
  • Capacity
  • Various sizes available
  • Machine Weight
  • 500 g to 2 kg (depending on product type)
  • Test Speed
  • Manual/As per Standard
  • Test Width
  • Varies by accessory (typically 1050 mm)
  • Test Stroke
  • Standard, up to 150 mm
  • Control Mode
  • Manual
  • Environmental Aspect
  • RoHS compliant, eco-friendly formulation
  • Color Options
  • Black, Red, White (contrast)
  • Product Types Available
  • Black Ink, Red Paste, White Contrast Paint, Dry Powder, Aerosol Sprays
  • Compliance
  • Conforms to ASTM E709, IS 6410 standards
  • Shelf Life
  • 24 months from manufacturing date
  • Packaging Size
  • 100 mL, 400 mL spray, 1 L bottle, 5 L can (as applicable)
  • Safety
  • Non-toxic, non-corrosive, low odor (refer MSDS)
  • Storage Condition
  • Store in cool, dry place below 40°C
  • Magnetic Response
  • Extra fine particles for maximum sensitivity
 
 

About MPI Consumables



Explore the illustrious range of MPI Consumables, offering the latest advancements for Magnetic Particle Inspection. Available in superlative types-Black Ink, Red Paste, White Contrast Paint, Dry Powder, and Aerosol Sprays-these products guarantee unbeatable sensitivity with extra fine particles. Each consumable conforms to ASTM E709 and IS 6410 standards, ensuring reliability for manual or standard-compliant inspections. Our eco-friendly, RoHS-compliant formulations boast high safety standards: non-toxic, non-corrosive, and low odor. With multiple packaging sizes and color options, these consumables deliver consistent, high-quality results with immediate response and effortless application-truly the hallmark of MPI excellence.

Primary Advantages & Specific Usages of MPI Consumables

MPI Consumables are designed for both general and specific Magnetic Particle Inspection (MPI) testing applications. Superlative product sensitivity ensures clear flaw detection, while compliance with ASTM and IS standards enhances reliability. They are ideal for exporters, manufacturers, and service providers, offering unbeatable versatility and safety. Products are manually operated, suitable for single or multiple specimens, and guarantee efficient, consistent results in diverse industrial settings.


Logistics & Packaging for MPI Consumables: Drop-off, Outlay, and Samples

MPI Consumables are ready for global dispatch, with standard drop-off via Indian FOB ports. Various packaging options, from 100 mL bottles to 5 L cans, offer flexibility to suit any outlay or purchase order. Each order is securely packed for transit and storage. Our sample policy enables clients to request product samples before final outlay commitments, ensuring satisfaction and confidence prior to a full-scale purchase.


FAQ's of MPI Consumables:


Q: How should MPI Consumables be stored to maximize shelf life?

A: MPI Consumables must be stored in a cool, dry place below 40C to maintain their 24-month shelf life. Always follow storage instructions on the packaging.

Q: What types of MPI Consumables are available for different contrast needs?

A: We offer black ink, red paste, white contrast paint, dry powder, and aerosol sprays, each formulated for maximum sensitivity and available in multiple color options to suit various inspection requirements.

Q: Where do MPI Consumables conform in terms of quality standards?

A: All MPI Consumables meet the strict requirements of ASTM E709 and IS 6410, guaranteeing superlative performance and reliable inspection results.

Q: What are the primary benefits of using MPI Consumables in NDT testing?

A: The benefits include immediate response upon application, extra fine particle sensitivity for accurate defect detection, easy application, and eco-friendly, non-toxic formulations.

Q: What is the process for placing a purchase order and sample request?

A: You may submit a purchase order for required quantities and packaging sizes. Our sample policy allows you to request samples prior to major outlay, ensuring the product meets your inspection requirements.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Testing & Measuring Equipment Category

Carbon Determination Apparatus

Carbon Determination Apparatus

Usage : Chemical analysis laboratory

Application : Analysis of carbon content in ferrous or nonferrous metals, ores, alloys, and other materials

Control Mode : Manual

Accuracy : 0.05% (depending on procedure)

Automation Grade : Manual

Interface Type : Manual operation, no digital interface

Sand Siever

Sand Siever

Usage : Testing granularity of sand

Application : Sieving and grading of sand

Control Mode : Manual

Accuracy : 1 mm

Automation Grade : Manual

Interface Type : Manual operation

Digital Coating Thickness Gauge

Digital Coating Thickness Gauge

Usage : Paint, powder coating, electroplating thickness measurement

Application : Coating thickness measurement on metallic substrates

Control Mode : Digital Button Control

Accuracy : (2%+1 m)

Automation Grade : Manual

Interface Type : None (no PC interface)

Dewinter Camera

Dewinter Camera

Usage : Laboratory, Education, Medical, Metallurgy

Application : Microscopy Imaging, Research, Laboratory Analysis

Control Mode : USB & Software Controlled

Accuracy : 1.3 Megapixel (resolution dependent)

Automation Grade : Manual

Interface Type : USB 2.0